Since welding fume was classified as a cause of lung cancer and HSE raised its enforcement expectations in 2019, every welding risk assessment has to show how fume is controlled at source, not just that a mask is available. This page gives the hazards and controls for arc welding indoors and outdoors, following HSE's guidance on controlling the risks from welding, and a sequence for the method statement.
Based on HSE — Controlling the risks from welding, read 2026-10-18. This page is a starting point you must adapt to your own site, people, equipment and the client's rules. It is not a substitute for an assessment by a competent person.
Hazards and controls
| Hazard | Who is at risk | Controls |
|---|---|---|
| Welding fume — indoors | Welders, others in the workshop | Capture fume at source with local exhaust ventilation: on-torch extraction for MIG, extracted benches, extracted booths for larger work, or movable LEV with a swing-arm hood. Air discharged back into the workroom is filtered; air discharged outside leaves at a height that disperses it. |
| Welding fume — where LEV cannot control it | Welders | Suitable respiratory protective equipment: a powered or supplied-air respirator with an assigned protection factor of at least 20 for arc welders; an FFP3 may be adequate for under an hour on a clean-shaven wearer but does not protect against welding gases. RPE face-fit tested and managed under an RPE programme. |
| Welding fume — outdoors | Welders, people nearby | LEV cannot be relied on outdoors: suitable RPE provided and the protection of nearby people considered. |
| Fire and explosion | Everyone on site | Combustibles cleared or screened; flammable vapours excluded; fire extinguisher at the workstation; a fire watch during and after the work; hot-work permit where the site requires one. |
| Arc radiation (arc eye, skin burns) | Welders, passers-by | Welding helmet with the correct shade; screens around the work area; long-sleeved flame-resistant clothing and gauntlets. |
| Electric shock | Welders | Equipment inspected before use; dry gloves and insulated footwear; welding return clamp close to the work; damaged leads taken out of service. |
| Compressed gas cylinders | Welders, site | Cylinders secured upright; flashback arrestors fitted; valves closed when not in use; stored away from heat and ignition. |
Method statement — sequence of work
- Metal to be welded, process and duration recorded; the fume control chosen from them (on-torch, bench, booth, movable hood or RPE).
- LEV checked before the shift — airflow indicator in range, hood positioned within its capture zone; RPE checked and the wearer's face-fit record current.
- Area cleared of combustibles and screened; extinguisher placed; permit signed where used.
- Fire watch kept during the work and the area re-checked after it ends; LEV examined and tested at the intervals the regulations require.
What to include in the written assessment
- Site address, the task, the date and who carried out the assessment.
- Each hazard above with the people at risk, the controls in place and the residual risk rating.
- The equipment, PPE and competence (training, cards) the controls depend on.
- Emergency and rescue arrangements, first aid and the nearest A&E.
- A review date and a signature line for the person in charge and the operatives who have read it.
Get the document
Download the free risk assessment template (Word) and fill in the table above for your job, or have the RAMS generator produce a completed risk assessment and method statement for this trade in Word for £19.
Questions
Is an FFP3 mask enough for welding?
Only for short work (under about an hour) on a clean-shaven wearer, and it does not protect against welding gases. For regular arc welding HSE's preferred option is a powered or supplied-air respirator with an APF of at least 20, used alongside LEV.
Does welding outdoors remove the fume risk?
No. HSE states that LEV cannot be relied on to capture fume outdoors, so RPE is needed and the people nearby have to be protected too.